Edel K2 controllers: electric, hydraulic and gearless

"Edel K2 hydraulic controller, S/D, 80 A, re-levelling with doors open." Each term of this designation has a precise meaning, and decides whether the controller will fit.

SODILIFT editorial team · Technical notes for installers · Reading time: 7 min

Edel K2 controllers: electric, hydraulic and gearless

Four families, four manuals

The K2 range covers all four lift technologies, with a separate installation manual for each. K2 controllers drive installations in simplex, duplex, triplex or quadruplex.

  • Two-speed electric: the oldest solution, driven by contactors. K2 64200 manual.
  • Variable-frequency electric (3VF): speed is managed by a drive. K2 643VF manual.
  • Gearless: machine without gearbox, usually without a machine room. K2 Gearless manual.
  • Hydraulic: the car is pushed by a ram. K2 64230 manual.

D/S and S/D: two ways to start the pump

On hydraulic controllers, these abbreviations appear in every designation. They indicate how the pump motor is started, and the K2 64230 manual names them explicitly:

  • Direct start (D/S): the motor receives full voltage at once. It is simple, but the inrush current is high. Manufacturer reference 64232.
  • Star-delta (S/D): the motor starts in star, at reduced voltage, then switches to delta. The inrush current is much lower. Manufacturer reference 64234.

The choice is not free: it depends on the motor power and on what the electricity supply allows. At high power, star-delta is often required. A direct-start controller does not replace a star-delta one without rewiring the power circuit.

Watch the notation. Depending on the document, direct start may appear as A/D or D/D, and star-delta as E/T or E-T (Spanish abbreviations). They are the same starting modes.

Re-levelling, and why "with doors open"

A hydraulic lift drifts. The oil cools, the ram drops a few millimetres and the car is no longer level with the landing: hence the step you feel when stepping out.

Re-levelling corrects this difference automatically. "Re-levelling with doors open" means the correction can be made while the doors are open, that is, while users are getting in and out. This is what makes the drift unnoticeable.

Controllers without re-levelling also exist, for installations that are not equipped for it. It is not an option that can be added later by changing the controller alone: re-levelling requires the matching position detection in the shaft.

The current rating: the value that decides

Every designation includes a current rating, for example 25, 38, 50, 65, 80, 115 or 150 A. It is the rating of the up contactor, and it must match the installed motor.

It is read on the motor rating plate. Undersizing causes overheating and rapid contact wear; oversizing costs more for no benefit and weakens protection.

What to note before ordering a controller

  • the lift technology: two-speed, 3VF, gearless or hydraulic;
  • the supply voltage: 230 V or 400 V;
  • the motor current and power, read on its rating plate;
  • for hydraulics: the starting mode (direct or star-delta) and whether there is re-levelling;
  • the number of stops and the group type (simplex, duplex…).

A reference to confirm, a project to study? Send us photos or drawings: we will reply with a proposal.

WhatsApp Contact

Frequently asked questions

Can I add re-levelling by changing only the controller?

No. Re-levelling needs the matching position detection in the shaft; it is studied with the whole installation.

Where do I read the motor current?

On its rating plate, together with voltage and power. These are the three values to send us to choose the controller.

A lift project?

Send us your drawings: we study your project and send you a detailed offer.