Lift out of service: the first checks

A lift that has stopped is not always broken down. Here is the check sequence given in the Edel troubleshooting manual, and the line not to cross.

SODILIFT editorial team · Technical notes for installers · Reading time: 5 min

Lift out of service: the first checks

Warning. This article describes visual checks from the landing and the machine room. Any work in the shaft, on the car, on the safety circuit or on a live controller must be carried out only by a qualified lift technician. If someone is trapped in the car, call the maintenance company immediately: never try to open a landing door.

The check sequence

The Edel troubleshooting manual sets out a simple progression, from the most likely cause to the least likely. It starts with the state of the safety devices.

  1. Check the safety devices on the control panel. On the controller, a row of indicator lights represents the safety chain. The manual names lights 41, 40 and 39: if they are off, the chain is open somewhere.
  2. Check that the landing doors are properly locked. This is the most frequent cause. A door that has not closed properly, an object stuck in the sill or a misaligned roller is enough to open the chain.
  3. Make sure nothing is sticking out of the car. A box, a pushchair or a long object that stops the door from closing fully.
  4. Reset the lift. Switch off the main circuit breaker on the controller door, wait one minute, then switch it back on.

Why the safety chain cuts everything

A lift only starts if all its safety contacts are closed at the same time: the lock of each landing door, the car door contact, emergency stops, limit switches, the safety gear and the overspeed governor.

They are wired in series. A single open contact stops the lift, whatever the severity: an object in the sill causes exactly the same stop as a serious fault. This is deliberate: the system never assumes that a fault is minor.

After a power cut

In the event of a power cut, the manual refers to the rescue procedure to move the car. This procedure is specific to each type of lift: the K2 Gearless manuals, for example, describe one automatic evacuation and two manual evacuations, depending on whether the brake runs on 220 V DC or AC.

It is carried out by a trained person, with the lift manual at hand. It is never improvised.

When to call, and with what information

If the four checks do not bring the lift back into service, the diagnosis is no longer a job for the owner or the building manager. To save the technician time, note:

  • on which floor the car has stopped, with the doors open or closed;
  • which controller lights are on and which are off;
  • whether the stop followed a power cut, a storm or a particular operation;
  • how long the lift has been out of service, and whether the fault has happened before.

In most countries, every lift in service must be covered by a maintenance contract: that company is the one to call.

A reference to confirm, a project to study? Send us photos or drawings: we will reply with a proposal.

WhatsApp Contact

Frequently asked questions

Can I reset the main circuit breaker myself?

The manual lists it among the first checks: switch it off, wait one minute and switch it back on. If the lift does not return to service, do not insist and call the maintenance company.

What should I do if someone is inside the car?

Call the maintenance company or the lift's emergency service immediately. Never open a landing door: the evacuation is carried out by a trained person.